Third Examiner
What you receive

Examiner report

Verdict and grade, major and minor comments with evidence, copied and AI-sounding text, the fix list in order.

Sample report. The thesis, its data and every reference below are fictional.

Third ExaminerREF. TE-0000 · CONFIDENTIAL
Examiner report · before the defense

Shear bond strength of a bulk-fill resin composite to dentin using four adhesive protocols: an in-vitro study

MSc thesis · Dentistry · fictional sample · Standard: CRIS
VerdictMajor revision.Not ready to defend as written.
Why this grade · the three reasons
  1. 1The main conclusion is not supported: the "best adhesive" is not better than the control (A vs C, p = 0.925).
  2. 2A key mean in Table 4.2 cannot be computed from your raw data (12.58 reported, 15.28 recalculated).
  3. 3Methods say 10 specimens per group; your sheets hold 9.
References · fact-checkedScored 7 / 10
Raw data · recomputed2 numbers don't match
Fix list3 must-fix, in order
AI and softwareReview
reviewed ✓Final review · a dentist
Independent. Not affiliated with any university. Grades evidence, not people.Third Examiner · fictional sample · p. 1 of 7
THIRD EXAMINER · EXAMINER REPORTC · 59%p. 2 of 7
SECTION 2

Major comments in order of impact

M1
CRITICALEvidence T04
"C gave the highest bond strength, significantly above A" is not supported. A is highest (18.97 vs 18.33 MPa); Tukey A vs C, p = 0.925.
Do this: rewrite the conclusion. C is comparable to the control, not superior.
M2
CRITICALEvidence D02 · H1
Group B mean 12.58 MPa cannot be computed from the raw sheets. Recalculated: 15.28 (likely swapped digits).
Do this: correct the mean to 15.28 in Table 4.2, the text and the abstract.
M3
MAJOREvidence INV-1
Methods state n = 10 per group; the sheets hold 9 per group (36 specimens). Exclusions are not reported, as CRIS requires.
Do this: state n = 9 per group and report each excluded specimen with its reason.
SECTION 3

Minor comments

MINOR
Group D reports the standard error (0.82) as the SD (2.46). Label the column correctly and give the SD.
D03
MINOR
Normality and equal-variance checks are not reported. Both pass (Shapiro p ≥ 0.395, Levene p = 0.647), so the ANOVA stands. Add one sentence to the methods and the values to the results.
A01
MINOR
Reference [14]: Cited for '10,000 thermocycles equal one year in the mouth'; the source reports a range and does not state this equivalence.
T11
MINOR
Reference [22]: Year and volume do not match the DOI record.
T12
CriticalMajorPassed / fineThird Examiner · fictional sample · p. 2 of 7
THIRD EXAMINER · EXAMINER REPORTC · 59%p. 3 of 7
SECTION 4

Statistics: what changes and why

ITEMAS WRITTENbecomesCHANGE TOWHY
Conclusion, C vs AC significantly above A→C comparable to ATukey A vs C: difference 0.64 MPa, p = 0.925. A has the higher mean.
Group B mean12.58 MPa→15.28 MPaMean of the 9 raw values. The typed value has the same digits in a different order.
Specimens per groupn = 10→n = 9The sheets hold 9 per group. F(3, 32) also only fits 36 specimens.
Group D spreadSD 0.82→SD 2.46 (SE 0.82)0.82 equals the SD divided by √9: that is the standard error.
Assumption checksNot reported→Report themShapiro–Wilk lowest p = 0.395; Levene p = 0.647. Both pass.
One-way ANOVAF(3, 32) = 24.21=KeepRecomputed from the raw data: F = 24.21, p < 0.001.

Recomputed means from the raw sheets (MPa, n = 9 per group, line = ± 1 SD)

A vs CThe two dark bars are statistically the same (p = 0.925). The thesis says C is higher; the data say it is not.

Recomputed Tukey comparisons

A vs BDIFFERENT
Δ 3.69 MPa · p = 0.006
A vs CSAME
Δ 0.64 MPa · p = 0.925
A vs DDIFFERENT
Δ 7.88 MPa · p < 0.001
B vs CDIFFERENT
Δ −3.05 MPa · p = 0.029
B vs DDIFFERENT
Δ 4.19 MPa · p = 0.002
C vs DDIFFERENT
Δ 7.24 MPa · p < 0.001
Significant at 0.05 = DIFFERENTThird Examiner · fictional sample · p. 3 of 7
THIRD EXAMINER · EXAMINER REPORTC · 59%p. 4 of 7
SECTION 5

Originality: copied text and AI-sounding writing

COPIED TEXT · T15
2 sentences without quotation marks
Compared with every source the thesis cites
AI-SOUNDING WRITING · T16
2 passages flagged
Each with the reason, read by a person
COPIED TEXTDiscussion, paragraph 2T15
Two sentences follow the abstract of [7] almost word for word. They are cited, but not in quotation marks.
Do this: put them in quotation marks, or rewrite them in your own words and keep the citation.
AI-SOUNDINGIntroduction, paragraph 1T16
"In the ever-evolving landscape of adhesive dentistry, it is crucial to delve into…"
Why: a stock opener with no fact in it.
Do this: open with the gap: few studies test universal-adhesive modes under a bulk-fill composite.
AI-SOUNDINGDiscussion, paragraph 5T16
Furthermore,Moreover,Additionally,
Why: three sentences in a row open this way and repeat the paragraph above.
Do this: cut them to one sentence that states how your result compares with earlier studies.
How to read this page. The copied-text check compares the thesis with the sources it cites; it does not replace your university's similarity report. AI-sounding flags are a reader's judgement on style, each with its reason. They are not a detector score and not an accusation.
This review grades evidence, not people.Third Examiner · fictional sample · p. 4 of 7
THIRD EXAMINER · EXAMINER REPORTC · 59%p. 5 of 7
SECTION 6

Section-by-section critique

SECTIONWHAT WORKSWHAT TO CHANGE
Title and abstractThe title names the material, the test and the comparison.CRITICAL The abstract repeats the unsupported conclusion (M1) and the wrong group B mean (M2).
IntroductionThe gap is clear: few studies pair universal adhesive modes with a bulk-fill composite.State the null hypothesis for each comparison, not one general aim.
MethodsAdhesive protocols and ageing (5,000 thermocycles) are described step by step.Correct n to 9, add an exclusion log, a sample-size justification and the assumption checks.
ResultsThe ANOVA is reported in full: F(3, 32) = 24.21.CRITICAL Correct Table 4.2 and remove the claim that C is above A.
DiscussionCompares the findings with earlier bond strength studies.Rebuild the argument on "comparable to the control"; drop the equivalence cited to [14]. Rewrite paragraphs 2 and 5 (section 5).
ConclusionShort and direct.Rewrite it to match the data: A and C are statistically the same; D is lowest.
SECTION 7

Ethics and compliance

OK
Source of the extracted teeth and the ethics approval are stated in the methods.
ADD
Donor consent wording for the use of extracted teeth is not given. Add one sentence naming how consent was obtained.
ADD
Conflict-of-interest and funding statements: the adhesives are named by type only; add a statement that no manufacturer funded the study, if true.
SECTION 8

Tables and figures

FIX
Table 4.2: correct the group B mean and the group D SD; put n = 9 in the caption.
ADD
Add the Tukey letters (shared letter = not significantly different) to Table 4.2 so the reader sees that A and C share a letter.
FIX
The bar chart of means should show SD error bars, labelled as SD.
This review grades evidence, not people.Third Examiner · fictional sample · p. 5 of 7
THIRD EXAMINER · EXAMINER REPORTC · 59%p. 6 of 7
SECTION 9

References

WRONG CLAIM
[14] Cited for '10,000 thermocycles equal one year in the mouth'; the source reports a range and does not state this equivalence.
FIX DETAILS
[22] Year and volume do not match the DOI record.
COPIED TEXT
[7] Supports its sentences, but two of them copy its abstract without quotation marks (section 5).
KEEP
All other references support the sentence they are cited for. Full list in the journal-submission audit.
SECTION 10

Plain explanation for the student

Your experiment is good and your main test is right. But your conclusion picks the wrong winner: the control bonded best, and the universal adhesive in etch-and-rinse mode was statistically the same. "Comparable to the gold standard" is a strong, defensible finding. Claiming it is better is what an examiner will stop you on.

The other two problems are typing problems, not science problems: one mean has its digits in the wrong order, and the methods count one more specimen per group than your sheets hold. Both are quick to fix, but an examiner who finds them will check every other number.

SECTION 11

Must-fix before the defense, in order

  1. 1
    Rewrite the conclusion: C is comparable to A, not superior.
  2. 2
    Correct the group B mean to 15.28 in Table 4.2 and the abstract.
  3. 3
    State n = 9 per group and report the excluded specimens.
  4. 4
    Report the group D SD as 2.46.
  5. 5
    Add the normality and equal-variance results.
  6. 6
    Replace or reword the sentence cited to [14]; correct the details of [22].
  7. 7
    Quote or rewrite the two Discussion sentences that follow [7], and rewrite the passages that read as machine-written.
This review grades evidence, not people.Third Examiner · fictional sample · p. 6 of 7
THIRD EXAMINER · EXAMINER REPORTC · 59%p. 7 of 7
SECTION 12

Evidence index nothing here is opinion without a check behind it

IDWHAT WAS CHECKEDUSED IN
INV-1Specimen inventory: 9 per group on the raw sheets, 36 in total, no exclusion log.M3
D02Group B mean recomputed from the 9 raw values: 15.28.M2
H1Origin of 12.58: the same digits as 15.28, two swapped.M2
D03Group D spread recomputed: SD 2.46, SE 0.82.Minor
A01Normality and equal-variance checks on the raw data: lowest Shapiro–Wilk p = 0.395, Levene p = 0.647.Minor
T04Tukey A vs C recomputed: difference 0.64 MPa, p = 0.925.M1
T11Reference [14] read against its sentence.Minor
T12Reference [22] checked against its DOI record.Minor
T15Thesis text compared with the cited sources: two sentences follow [7] without quotation marks.Originality
T16Writing read for passages that sound machine-written: two flagged, with reasons.Originality

Recomputed descriptives (MPa, from the raw sheets)

GROUPNMEANSDSEMINMAX
A · Two-step etch-and-rinse adhesive (control)918.971.450.4816.6020.80
B · Universal adhesive, self-etch mode915.282.430.8110.3218.75
C · Universal adhesive, etch-and-rinse mode918.332.280.7614.2920.97
D · One-step self-etch adhesive911.082.460.827.6515.08
Every ID points to a check in the audit trail.Third Examiner · fictional sample · p. 7 of 7